2 Switch Step Scan Setup Instructions
Settings>Input>Scanning
- check Enable Scanning
- choose Switch Access Menu
- choose Switch Configuration and choose appropriate option
- turn off Auto Scan
- if using a bluetooth switch, choose Keyboard Switch and set up your switches
- turn Auditory Prompts on and set up, if needed
- choose Patterns
- Mode, choose appropriate way you want the page to be scanned
- modify the remaining pattern options as apporpriate for your client
- Scan Timing
- Scan Speed needs set to a large number for step scanning
- Number of Re-scans N/A for step scanning
- Activation Delay, turn on to offer a chance to correct a mistake
- Auto Restart, N/A for step scanning
Troubleshooting
Use Case: Team is using two switch scanning with clients who have very high tone.
Problem: When the select down on the "go/drive" switch the scan keeps going, which they don't want.
Resolution: Increase the Scan Speed to a high speed, e.g 10